Model | Cat. # | Description | List Price | Quantity/Status | Distributor Stock Check |
---|---|---|---|---|---|
L101 | 2126.02 | Simple Logger® II Model L101 | $0.00 Sale: $0.00 |
Discontinued |
|
|
Channels | One |
Input | BNC |
Ranges (2) | 10mV to 1VAAC |
Accuracy (50/60Hz) | 10 to 50mV ±(0.5% R +1mV) 50 to 1000mV (0.5% R +0.5mV) |
Resolution | 0.1mVAC |
Maximum Input Voltage | 5Vrms or ± 7.07VPEAK |
Input Impedance | 800kΩ |
Sample Rate | 64 samples / cycle |
Storage Rate | Programmable from 125ms to 1 per day |
Storage Modes | Start/Stop, FIFO, extended mode (XRM) and Alarm |
Recording Length | 15 minutes to 6 weeks, programmable using DataView |
Memory | 240,000 measurements (512KB). Recorded data is stored in non-volatile memory and will be retained even if battery is low or removed. |
Communication | USB 2.0 optically isolated |
Power Source | 2x1.5V AA (LR6) alkaline batteries |
Battery Life | 100 hours to >45 days (depending of sample rate/recording length) |
Dimensions | 5.38 x 2.75 x 1.28” (136 x 70 x 32mm) |
Sensor | Optional current probe with BNC output (SR661, SL261, MN261) |
Weight (with battery) | 6.4 oz (180g) |
Case | Polycarbonate |
Operating Temperature | 14° to 122°F (-10° to 50°C) |
Storage Temperature | -4° to 140°F (-20° to 60°C) |
Relative Humidity | Up to 85% @ 95°F (35°C) |
Ingress Protection (IP) | IP40 |
EMC | EN 61326-1 |
Safety Compliance | IEC 61010-1, EN 61010-2-32 600V CAT III ; Pollution Degree 2 |
User Manuals
Quick Start Guides
Datasheets
Brochures
Comparison Charts
Software
DataView® Software
Ver. 3.63.0010 | Models Supported by DataView
Release Date: November 04, 2024
DataView® Complete
Contains report generation and ALL DataView® control panels. If you don't want to download the entire DataView® package, simple scroll below to locate individual component installers.Self-extracting Executable: v3.63.0010 .exe — We recommend you use the executable file to simplify the installation process. Click on the link to download it, double-click on the downloaded .exe file to begin the installation process, and follow the installation prompts.
Zipped File: v3.63.0010 (1.8 MB). zip — Alternatively you can manually extract the files from the zipped file. Please note: you should NEVER install these files from within the zipped file. You MUST extract them prior to installing.
IMPORTANT:
- Back-up all template files before installation to ensure that they do not get overwritten.
- Uninstall previous version of DataView before installing a new version.
- PQL Loggers and Sentinel Series are no longer supported by DataView. See bottom of the page for a compatible version
Supported Operating Systems:
Windows 10 (32 & 64 Bit)
Widows 11 Pro
Minimum System Requirements
Below are the individual DataView component installers
This is the DataView core report generation software without any control panels
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 1110, 1246, 1227, 1510, 1550, 1821, 1822, 1823, L452, DL913, and DL914
Download v2.02.0303 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports model 8510
Download v1.02.0006 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports model 6417
Download v1.02.0011 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 6470, 6470-B, 6471, 6472, and 6474
Download v1.06.0009 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 6116, 6116N, and 6117
Download v1.07.0022 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 1060, 5060, 5070, 6550, 6555, 6526, 6532, and 6534
Download v4.02.0086 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 6240, 6250, 6255, and 6292
Download v1.07.0005 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 8220, 8230, 3945, 3945-B, 407, 607, and 8335 (if using firmware ≤2.8)
38MB Download v3.08.0019 .zip format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 8333, 8335 (if using firmware >2.8), 8336, 8435, 8436
Download v1.08.16142 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: 8345
Download v1.6.16272 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: PEL 52, PEL 102, PEL 103, and PEL 105
Download v2.09.16216 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
This control panel supports models: L261, L264, CL601, L702, L101, L102, L104, L642, L111, L432, AL834, ML912, ML914, L322, L562, L564, L404, and L481
Download v1.05.0014 .exe format
This control panel requires DataView version 3.61.0008 or higher to access reports.
NOTE: You must install DataView® core prior to installing and using a DataView® Control Panel.
NOTE: PQL Loggers and Sentinel Series are no longer supported by DataView.
To obtain an older version of DataView that is compatible for these instruments, click the link below:
Download v3.09.0008 - .zip format
Supported Operating Systems:
Windows 8/8.1 (32 & 64 Bit)
Windows 10 (32 & 64 Bit)
LabView Drivers
Procedures for installing the LabView drivers. LabView Installation PDF
Digital Multimeters - MTX-3292B, MTX3292BT, MTX3293B, MTX3293-BT | |||
Ver. 1.0 | LabView Drivers | ||
Megohmmeters | |||
Ver. 1.0 | Model 1060 | Overview PDF | |
Ver. 1.1 | Models 5060 & 5070 | Overview PDF | |
Ver. 1.0 | Models 6550 & 6555 | Overview PDF | |
Power Quality & Energy | |||
Ver. 1.0 | Models 8333, 8435, 8335, & 8336 | Overview PDF | |
Ver. 1.0 | Models PEL 102 & 103 | Overview PDF | |
Simple Logger II Series | |||
Ver. 1.0 |
Overview PDF | ||
SCOPIX IV – OX9000 Series | |||
Ver. 1.0 Ver. 1.0 |
Application Notes
Forms
Firmware
Technical Bulletins
Videos
What's New in DataView 3.50
Introduction To Data Loggers
Model | Cat. # | Description | List Price | Quantity/Status | Distributor Stock Check |
---|---|---|---|---|---|
JM861 | 2110.90 | AC Current Probe Model JM861 (30A, 10mV/A; 300A, 1mV/A & 3000A, 0.1mV/A, BNC) |
$790.00 | Consult Factory for Availability |
|
1000-24-1-1 | 2112.39 | AmpFlex-1000A, 24", 1mV/A | $455.00 | Consult Factory for Availability |
|
300-24-2-10 | 2112.88 | AmpFlex-30/300A, 24", 100mV/10mV/A | $499.00 | Consult Factory for Availability |
|
30000-24-2-0.1 | 2113.33 | AmpFlex-3000/30000A, 24", 1mV/0.1mV/A | $529.00 | Consult Factory for Availability |
|
SR661 | 2113.49 | AC Current Probe Model SR661 (10A, 100mV/A; 100A, 10mV/A & 1000A, 1mV/A, BNC) |
$369.00 |
|
|
MN375 | 2115.41 | AC Current Probe Model MN375 | $288.00 |
|
|
MN255 | 2115.81 | AC Current Probe Model MN255 | $235.00 | Consult Factory for Availability |
|
MN261 | 2115.82 | AC Current Probe Model MN261 (20A, 100mV/A & 200A, 10mV/A, BNC) |
$269.00 |
|
|
MN353 | 2116.27 | AC Current Probe Model MN353 | $273.00 |
|
|
SR752 | 2116.32 | AC Current Probe Model SR752 | $380.00 |
|
|
SR759 | 2116.33 | AC Current Probe Model SR759 | $455.00 |
|
|
2118.09 | Case – General Carrying Case — Dimensions: (13 x 9.5 x 3) in | $73.50 |
|
|
|
2118.46 | Adapter - Banana (Female) - BNC (Male) (XM-BB) for use with AmpFlex Sensors, Models K100/K110 and SLII Data Loggers (600V CAT III) |
$46.25 |
|
||
2126.49 | Cable – Replacement USB (type A to 5-pin mini-B) cable for Simple Logger® II series and Model 1950 (RoHS Compliant) | $16.00 |
|
|
|
2133.72 | Small Classic Tool Bag for field use. 12 Exterior and 14 Interior pockets. Dimensions: (13.0 x 9.8 x 9.5) in. For use with PEL Models: PEL 102 and PEL 103, DMM/Oscilloscope/Power Analyzer Model: OX 5042B, Megohmmeters Models: 5050, 5060, 5070 & 6505, 6550 & 6555.Data Loggers Models: DL913 & DL 914. |
$38.00 |
|
|
|
MN93-BK | 2140.32 | AC Current Probe Model MN93-BK for Models 3945/3945-B, 8220, 8230, 8333, 8335, 8336, 8345, 8435, PEL Series, L104 & L564 | $252.00 |
|
|
MN193-BK | 2140.36 | AC Current Probe Model MN193-BK for Models 3945/3945-B, 8220, 8230, 8333, 8335, 8336, 8345, 8435, PEL Series, L104 & L564 | $339.00 |
|
|
MN379 | 2153.01 | AC Current Probe Model MN379 | $299.00 |
|
|
1000-24-2-1 | 2112.98 | AmpFlex-100/1000A, 24", 10mV/1mV/A | $0.00 | Discontinued |
|
3000-24-2-0.3 DISCONTINUED | 2114.87 | AmpFlex-300/3000A, 24", 3.3mV/0.3mV/A DISCONTINUED | $0.00 | Discontinued |
|
MN251 | 2115.77 | AC Current Probe Model MN251 (200A, 1mV/A, Lead) |
$0.00 | Discontinued |
|
MN373 | 2116.28 | AC Current Probe Model MN373 | $0.00 | Discontinued |
|
MF 300-6-2-10 | 2126.81 | MiniFlex® 30/300A, 6", 100mV/10mV/A | $0.00 | Discontinued |
|
MN03 | 2129.18 | AC Current Probe Model MN03 (Discontinued replaced by Cat.#2129.19) | $0.00 | Discontinued |
|
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|