Model | Cat. # | Description | List Price | Quantity/Status | Distributor Stock Check |
---|---|---|---|---|---|
L104 | 2126.10 | Simple Logger® II Model L104 (Discontinued) | $0.00 Sale: $0.00 |
Discontinued |
|
|
ELECTRICAL | |
Channels | Four |
Input | One Connector per channel |
Voltage Range |
0 to 1VAC |
Resolution |
0.1A (1mv/A scale) |
Accuracy* |
0 to 10mV unspecified |
Maximum Input Voltage**** | 5Vrms (-7.07Vpeak to + 7.07Vpeak) |
Input Impendence | 100kΩ |
Sample Rate | 64 samples/cycle |
Storage Rate | Programmable from 125ms to 1 per day |
Storage Rate | Programmable from 200 ms to 60 minutes |
Storage Technique | Start/Stop, FIFO, Extended Recording Mode** (XRM™) and Store on Alarm |
Recording Length | 15 minutes to 8 weeks, programmable using DataView® |
Memory | 1,000,000 measurement (2MB) Recorded data is stored in non-volatile memory and retained even if the battery is low or removed. |
Communication | Bluetooth (Class 2) |
Power Source | 4x1.5V C-cell alkaline batteries |
Battery Life | Up to > 180 days (dependent on storage rate and recording length)) |
MECHANICAL | |
Dimensions | 5.904 x 5.904 x 3.568" (150 x 150 x 91mm) |
Weight (with battery) | 2.1 lbs (0.95kg) |
Case | UL94-V0 |
Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) |
Shock | IEC 68-2-27 (30G) |
Drop | IEC 68-2-32 (1m) |
ENVIRONMENTAL | |
Operational Temperature | 14° to 122°F (-10° to 50°C) |
Storage Temperature | -4° to 140°F (-20° to 60°C) |
Relative Humidity | 0 to 85% @ 95°F (35°C), Non-condensing |
Altitude | 02000m |
SAFETY | |
Safety Rating | EN 61010-1; 600V CATIV; 1000V CAT III; Pollution Degree 2 |
Protection Degree | IP65 |
Electro-Magnetic Compatibility | EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004) |
*The native measurement of the instrument is voltage. This voltage is scaled to displace current by a factor that corresponds to the users probe selection. This accuracy specification does not account for probe errors.
**This unique recording mode provides the opportunity to continuously record over long periods of time by reducing the stored sample resolution of the oldest data and maintaining matching resolution for the newest data. Each time the memory fills up using XRM™, every other of the oldest stored samples is discarded making room for newer samples. This process continues until the recording is manually stopped.
***A memory backup capacitor provides backup power while the batteries are being changed. This backup capacitor will maintain the instrument for up to 10 seconds without batteries installed. If the unit is connected to DataView® via a PC, the battery life is 200 hours regardless of the storage rate.
****Voltages beyond this range may damage the instrument.
User Manuals
Quick Start Guides
Datasheets
Brochures
Comparison Charts
Software
Forms
Firmware
Technical Bulletins
Videos
What's New in DataView 3.50
Model | Cat. # | Description | List Price | Quantity/Status | Distributor Stock Check |
---|---|---|---|---|---|
2118.09 | Case – General Carrying Case — Dimensions: (13 x 9.5 x 3) in | $73.50 |
|
|
|
2118.49 | Adapter - 110V Outlet Adapter w/4mm Banana Plugs for Models L230, L260, L261, L562, 8220 & 8230 | $44.00 |
|
|
|
2133.72 | Small Classic Tool Bag for field use. 12 Exterior and 14 Interior pockets. Dimensions: (13.0 x 9.8 x 9.5) in. For use with PEL Models: PEL 102 and PEL 103, DMM/Oscilloscope/Power Analyzer Model: OX 5042B, Megohmmeters Models: 5050, 5060, 5070 & 6505, 6550 & 6555.Data Loggers Models: DL913 & DL 914. |
$38.00 |
|
|
|
MN93-BK | 2140.32 | AC Current Probe Model MN93-BK for Models 3945/3945-B, 8220, 8230, 8333, 8335, 8336, 8345, 8435, PEL Series, L104 & L564 | $252.00 |
|
|
SR193-BK | 2140.33 | AC Current Probe Model SR193-BK for Models 3945/3945-B, 8220, 8230, 8333, 8335, 8336, 8345, 8435, PEL Series, L104 & L564 | $434.00 |
|
|
MN193-BK | 2140.36 | AC Current Probe Model MN193-BK for Models 3945/3945-B, 8220, 8230, 8333, 8335, 8336, 8345, 8435, PEL Series, L104 & L564 | $339.00 |
|
|
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|